ETREL Charger
Easily set up your ETREL Charger with Smartmaster Pro using these recommended configuration steps.
To ensure a seamless connection between the ETREL Charger and Smartmaster Pro, follow these recommended configuration steps. This setup optimizes communication and guarantees reliable performance.
Configuration Tips
-
Enable IPv6 Connectivity:
- If using Windows, enable IPv6 connectivity.
- Access the charger using the URL:
http://<charger serial>.local/
- The serial number can be found inside the Inch Duo on the right panel.
-
Set Central System Endpoint URL:
- Go to the settings and set the Central System endpoint URL to:
ws://{SMARTMASTER_IP_ADDR}:8834/ocpp
- Go to the settings and set the Central System endpoint URL to:
-
Allow Remote Load Scheduling:
- Enable the option for the charge point operator to remotely set load schedules.
-
Select Sampled Meter Value Types:
- Choose the appropriate sampled meter value types for accurate monitoring and reporting.
These settings ensure optimal integration between the ETREL Charger and Smartmaster Pro. Configuring remote load schedules enhances flexibility and control.