Alfen EVE Double Charger
Set up your Alfen EVE Double Charger with Smartmaster Pro using these configuration steps.
To ensure a seamless connection between the Alfen EVE Double Charger and Smartmaster Pro, follow these recommended configuration steps. This setup optimizes communication and guarantees reliable performance.
Configuration Tips
-
Find the Serial Number:
- Locate the serial number from one of the following:
- Paper documents supplied with the charger.
- Identification label on the underside of the charging station.
- Locate the serial number from one of the following:
-
Enable Static Load Balancing:
- In ACE Devices Installer, navigate to settings and select:
- Static Load Balancing for optimized power distribution.
- In ACE Devices Installer, navigate to settings and select:
-
Set Back Office URL:
- Go to ACE Devices Installer > Back Office URL.
- Enter the Smartmaster IP as follows:
ws://X.X.X.X:8834/ocpp
-
Check Device’s IP Address:
- Ensure the device’s IP address is in the same network as the Smartmaster for seamless communication.
-
Configure Meter Value Sample Interval:
- In ACE Devices Installer > Connectivity > Meter Value, set:
- Meter Value Sample Interval to
60S
for accurate data sampling.
- Meter Value Sample Interval to
- In ACE Devices Installer > Connectivity > Meter Value, set:
-
Select Sampled Data for Meter Values:
- In ACE Devices Installer > Connectivity > Meter Value, configure:
- Sampled Data 1 =
Energy.Active.Import.register
- Sampled Data 2 =
Current.Import
- Sampled Data 3 =
Current.Offered
- Sampled Data 1 =
- In ACE Devices Installer > Connectivity > Meter Value, configure:
These settings ensure optimal integration between the Alfen EVE Double Charger and Smartmaster Pro. Proper configuration of the IP address, load balancing, and meter values enhances monitoring and reporting accuracy.