Bibus Charger
Set up your Bibus Charger with Smartmaster Pro easily using these recommended configuration steps.
To ensure a seamless connection between the Bibus Charger and Smartmaster Pro, follow these recommended configuration steps. This setup optimizes communication and guarantees reliable performance.
Configuration Tips
-
Find the Current IP Address:
- Locate the current IP address directly on the display of your station.
- Enter this IP address into your web browser.
- The Circontrol dashboard should now be displayed.
-
Deactivate Plug & Charge:
- By default, the Bibus station is set to Plug & Charge.
- Deactivate this setting in the Charge Point Manager.
-
Select OCPP Version:
- Under Available Integrations, select:
- OCPP 1.6J for communication with Smartmaster Pro.
- Under Available Integrations, select:
-
Name Configuration:
- Ensure that the name of your Bibus charging station does not contain spaces.
-
Set Host URL:
- In the Central System section, set the Host URL to:
ws://{SMARTMASTER_IP_ADDR}:8834/ocpp
- In the Central System section, set the Host URL to:
-
Meter Values Sample Interval:
- Under OCPP Settings, configure the Meter Values Sample Interval.
- Example: Set the interval to 60 seconds for accurate data collection.
These settings optimize the integration between the Bibus Charger and Smartmaster Pro, ensuring secure and reliable communication. Proper configuration of the OCPP version and meter values sample interval enhances monitoring and reporting.